Universal Reducer Test Bench

Adopts frequency conversion feedback loading system, energy feedback does not pollute the power grid. Ensures that the energy absorbed by the loading motor is fed back to the drive motor, with an electrical energy conversion efficiency of not less than 75%.

Constant torque (programmable) operation function through computer communication and control, fully meeting the requirements of loading tests.

High reliability test bench: Real-time status monitoring, 99.9% accurate alarm and intelligent fault diagnosis.

Perfect internal status display, making the system operation status transparent.

Complete fault self-diagnosis capability, automatically detecting fault points for maintenance personnel to find quickly and accurately.

Interlock alarm and interlock automatic shutdown functions, with an alarm accuracy of over 99.9%.

Specific Requirements Remarks
Speed Regulation: Supports stepless speed regulation of 0~3000r/min, stable operation at any speed for a long time; Step speed regulation: Speed up at preset rate, step loading after speed stabilization Covers full speed range
Load Regulation: Dynamic adjustment of load ratio; Can apply different proportional loads (manual or automatic) at fixed speeds for a long time Constant speed and variable load
Compatibility across speed ranges: Can apply different proportional loads at different speeds for a long time Variable speed and variable load
Bidirectional Function: Same accuracy and functions (speed regulation, loading, energy feedback) in forward/reverse modes; Energy feedback in both driving (positive drag) and loading (reverse drag) conditions Bidirectional energy recovery
Real-time Intervention: Supports manual setting of load size and change rate by users; Programmable logic for custom speed regulation/loading curves Automatic load spectrum
Shutdown Process: Gradual unloading → deceleration → shutdown Prevents system instability caused by sudden changes; Humanized design with smooth and shock-free segmental control of speed regulation and loading in automatic mode

 